REDUCING THE FAILURE RATE OF OCULAR PROSTHESIS AT HOSPITAL SULTANAH AMINAH

Authors

  • Muhamad Imran Abdulah Author
  • Ikmal Abdul Hakim Author
  • Rosni Amin Author
  • Rosliza Parumo Author
  • Ma Bee Chai Author
  • Rolzilah Rohani Author
  • Noraziyah Abdul Aziz Author
  • Hisyam Zainal Abidin Author

DOI:

https://doi.org/10.63719/qbulletin.v1i29.269

Keywords:

Ocular prosthesis, failure rate, Fabricated Iris Mould, eye conformer

Abstract

The Department of Oral & Maxillofacial Surgery at Hospital Sultanah Aminah, Johor Bahru started managing patients who lost their eyeballs with ocular prosthesis in 2013. Unfortunately, there was an increasing trend of failed ocular prosthesis from 2013-2015. The failure rate went from 28.6% in 2013 to 40% in 2014 and increased to 44.4% in 2015. Failed ocular prosthesis not only leads to dissatisfied patients but also an increase in cost due to redoing of prosthesis. The objective of this project was to reduce the incidence rate of failed ocular prosthesis. A failed case is when the prosthesis does not pass the issue stage and has to be redone from the beginning. The standard failure rate is 0%, as the average number of cases per year is only about 10 cases. We determined the contributing factors of failed ocular prosthesis by analysing retrospective data from patients’ dental and lab records. This was followed by a self-administered questionnaire on reasons for failed cases which was distributed among the dentists and lab technicians in our department. The contributing factors that were identified included insufficient knowledge or skill of dentist and lab technicians in the construction of the ocular prosthesis, as well as improper screening of new cases which was the main factor of all the failed cases. The strategies for change included improving the process of care by creating a checklist for proper screening of new patients, mentoring of new staff, and continuous training on construction of ocular prosthesis, Fabricated Iris Mould innovation technique and early referral for insertion of eye conformer. The interventions that were implemented reduced the failure rate to 20% in 2016 followed by 0% in 2017, 2018 and 2019. Ongoing efforts are being done to replicate this project in other Oral & Maxillofacial Surgery clinics in Johor.

Author Biographies

  • Muhamad Imran Abdulah

    Oral Maxillofacial Surgery Department, Hospital Sultanah Aminah, Johor Bahru, Johor

  • Ikmal Abdul Hakim

    Oral Maxillofacial Surgery Department, Hospital Sultanah Aminah, Johor Bahru, Johor

  • Rosni Amin

    Oral Maxillofacial Surgery Department, Hospital Sultanah Aminah, Johor Bahru, Johor

  • Rosliza Parumo

    Oral Maxillofacial Surgery Department, Hospital Sultanah Aminah, Johor Bahru, Johor

  • Ma Bee Chai

    Oral Maxillofacial Surgery Department, Hospital Sultanah Aminah, Johor Bahru, Johor

  • Rolzilah Rohani

    Oral Health District Office, Johor Bahru, Johor

  • Noraziyah Abdul Aziz

    Oral Health Division, State Health Department, Johor

  • Hisyam Zainal Abidin

    Oral Health Division, State Health Department, Johor

References

1. Goiato MC, Dos Santos DM, Bannwart LC, Moreno A, Pesqueira AA, Haddad MF, et al. Psychosocial impact on anophthalmic patients wearing ocular prosthesis. Int J Oral Maxillofac Surg. 2013 Jan 1;42(1):113–9.

2. Baino F, Perero S, Ferraris S, Miola M, Balagna C, Verné E, et al. Biomaterials for orbital implants and ocular prostheses: Overview and future prospects [Internet]. Vol. 10, Acta Biomaterialia. 2014 [cited 2020 Apr 15]. p. 1064–87. Available from: http://www.ncbi.nlm.nih.gov/pubmed/24342039

3. Catalu CT, Istrate SL, Voinea LM, Mitulescu C, Popescu V, Ciuluvică R. Ocular implants-methods of ocular reconstruction following radical surgical interventions. Rom J Ophthalmol. 2018 Apr 19;62(1):15–23.

4. Song JS, Oh J, Baek SH. A survey of satisfaction in anophthalmic patients wearing ocular prosthesis. Graefe’s Arch Clin Exp Ophthalmol [Internet]. 2006 Mar [cited 2020 Apr 15];244(3):330–5. Available from: http://www.ncbi.nlm.nih.gov/pubmed/16133031

5. Leatherbarrow B, Kwartz J, Sunderland S, Brammar R, Nichol E. The ‘baseball’ orbital implant: A prospective study. Eye [Internet]. 1994 [cited 2020 Apr 15];8(5):569–76. Available from: http://www.ncbi.nlm.nih.gov/pubmed/7835455

6. Groth MJ, Bhatnagar A, Clearihue WJ, Goldberg RA, Douglas RS. Long-term efficacy of biomodeled polymethyl methacrylate implants for orbitofacial defects. Arch Facial Plast Surg [Internet]. 2006 Nov [cited 2020 Apr 15];8(6):381–9. Available from: http://www.ncbi.nlm.nih.gov/pubmed/17116785

7. Meisler DM, Krachmer JH, Goeken JA. An immunopathologic study of giant papillary conjunctivitis associated with an ocular prosthesis. Am J Ophthalmol. 1981 Sep 1;92(3):368–71.

Downloads

Published

31-10-2020

Issue

Section

Articles

How to Cite

1.
REDUCING THE FAILURE RATE OF OCULAR PROSTHESIS AT HOSPITAL SULTANAH AMINAH. Q Bulletin [Internet]. 2020 Oct. 31 [cited 2026 Nov. 23];1(29). Available from: https://journal.nih.gov.my/index.php/qbulletin/article/view/269

Similar Articles

11-14 of 14

You may also start an advanced similarity search for this article.