Comparison of turnaround time (TAT) performance between Enzyme-Linked Immunosorbent Assay (ELISA) vs. Automated Chemiluminescent Immunoassay (CLIA) in measuring diabetes autoantibodies

Authors

  • Nadirah Zainal Abidin Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Raja Hasyidah Raja Bongsu Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Karniza Khalid Special Protein Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Nor Daliza Mohd Razali Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Stefannie Micheal Johnson Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Vaanhi Sandran Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Yuslina Mat Yusoff Haematology Unit, Cancer Research Center, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author
  • Saraswathy Apparow Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia Author

DOI:

https://doi.org/10.63719/imrj.2025.11.01.007

Abstract

Autoantibodies to glutamate decarboxylase (GAD), islet antigen-2 (IA2) and islet cell antigen (ICA) are characteristic markers for type 1 diabetes among paediatric populations and adults with latent autoimmune diabetes. We aim to compare the analysis performance of the enzyme-linked immunosorbent assay (ELISA) and the chemiluminescence immunoassay (CLIA) methods in the detection of diabetes autoantibodies. A cross-sectional study was conducted on 1,425 serum samples sent for diabetes autoantibodies measurement at the Institute for Medical Research, Kuala Lumpur, Malaysia, from April 2021 to July 2022. A total of 695 samples were measured using the Medizym® ELISA kit 96 wells and 730 samples were measured using Maglumi® CLIA kit. Both methods were able to produce timely results at more than 90% of the allowable laboratory turnaround time (LTAT). Cohen’s kappa showed good and satisfactory agreement between the two methods: 0.734 (GAD), 0.413 (ICA), 0.514 (IA2). Additionally, the CLIA method was significantly less time-consuming and less labour-intensive. CLIA method has a significant advantage over ELISA in offering better laboratory workflow with shorter time testing and TAT in laboratory practice.

Author Biographies

  • Raja Hasyidah Raja Bongsu, Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Science Officer in Endocrine Unit, SDC, IMR, NIH

  • Karniza Khalid, Special Protein Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Medical Dr in Speacial Protein Unit, SDC,IMR

  • Nor Daliza Mohd Razali, Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Medical Laboratory Technologies in Endocrine Unit

  • Stefannie Micheal Johnson, Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Medical Laboratory Technologies in Endocrine Unit

  • Vaanhi Sandran, Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    MEDICAL LABORATORY TECHNOLOGIST IN ENDOCRINE LAB

  • Yuslina Mat Yusoff, Haematology Unit, Cancer Research Center, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Head of Haematology Unit, CaRC, IMR, NIH

  • Saraswathy Apparow, Endocrine Unit, Specialised Diagnostic Center, Institute for Medical Research, National Institutes of Health, Ministry of Health, Setia Alam, 40170, Shah Alam, Selangor Malaysia

    Head of Endocrine Unit, SDC, IMR, NIH

Downloads

Published

09-09-2026

Issue

Section

Original Research Articles

How to Cite

Comparison of turnaround time (TAT) performance between Enzyme-Linked Immunosorbent Assay (ELISA) vs. Automated Chemiluminescent Immunoassay (CLIA) in measuring diabetes autoantibodies. (2026). International Medical Research Journal, 11(1). https://doi.org/10.63719/imrj.2025.11.01.007

Most read articles by the same author(s)